德旻科技有限公司~專業代理銷售各式工業儀表, 各式流量計及流量開關 / 液位傳送器及液位開關 / 壓力表, 差壓表, 壓力傳送器(開關), 差壓傳送器(開關) / 溫度傳送器(Pt100/1000)各式熱電偶, 溫度開關~~~
產品介紹

分析儀器 pH / ORP 傳送器(控制器) APM-1

COMPACT-LINE
For pH-Value, Redox, Standard signals and Temperature

Measuring range:
pH: -2 ... 16
Redox: -1500 ... +1500 mV
Pt100 / Pt1000: -50 ... +250°C
Standard signal: 0(4) - 20 mA / 0 - 10 V
Resistance: 100 Ω - 3 kΩ
Input:
1x pH/Redox
2x binary inputs
1x temperature / resistance / standard signal
Output:
2 relays (SPDT)
1 x power supply for 2-wire sensor 17 VDC
Optionanl plug-in boards:
analogue output, power supply, RS485, data logger, Profibus® PA, relays

Graphic display with backlight (max. 3 values, trend, bargraph), supply voltage for 2-wire sensors, freely programmable, math and logic module, with panel mounted housing or field mounted housing

導電度 / 濃度計 分析儀傳送器(控制器) ACM-1 / LCI

COMPACT-LINE
For Conductivity, TDS, Resistance,
Standard signals and Temperature


Measuring range:
Conductivity: 0 ... 200 mS/cm
Pt100 / Pt1000: -50 ... +250°C
NTC/PTC: 0.1 ... 30 kΩ                
Resistance: 100  Ω ... 3 kΩ
Standard signal: 0(4) ... 40 mA,  0 ... 10 V
Input:
1x conductivity / resistance / TDS
1x temperature / resistance / standard signal
2x binary inputs
Output:
2x relays (SPDT)
1 x power supply for 2-wire sensor 17 VDC
Optional plug-in boards:
Analogue output, power supply sensors, RS485,
data logger, Profibus® PA, relays

Supply voltage for 2-wire sensors, freely programmable,
math and logic module, panel mounted housing or field mounted housing, graphic display with backlight (max. 3 values, trend, bargraph)

Inductive Conductivity / Concentration
and Temperature Transmitter LCI

Measuring range: 0 - 500 µS/cm ... 0 - 2000 mS/cm
Connection: G 1¼ ... 2 male thread, screwed pipe connection DIN 11851, Tri-Clamp®, Varivent®
Material:
PEEK. PVDF

pmax: 10 bar
tmax: 120°C (short term 140°C)
Accuracy:
1 %

溫 / 濕 度傳送器 AFK-E

For Industrial applications,
capacitive method of measurement


Operating range temperature:
-40 ... +180°C (temperature)
0 ... 100% rF (humidity)
Accuracy:
±(1,3 + 0,3% of reading) % rF  at -15 ... +40°C / < 90% rF
±2,3  % rF  at-15 ... +40°C / > 90% rF
±(1,4 + 1% of reading) % rF  at -25 ... +70°C
±(1,5 + 1,5% of reading) % rF  at -40 ... +180°C
pmax: 15 bar
tmax: -40 ... 60°C (housing), -40 ... +180°C (sensor)
Output 0 ... 5 V, 0 ... 10 V, 4 ... 20 mA
Dew-point temperature, freezing point temperature, absolute humidity,
specific enthalpy, water-vapour partial pressure, mixing ratio
Communication: RS232