電磁式流量計 ALMAG

  • Line Sizes : 3/8" - 110" (6-2800mm)
  • Pressures : 580 psig(4.0Mpa) for line sizes up to 3" (80mm)
  • Temperatures : 5~+160 °F( -20~ +70 °C) - Integral,(-40 ~ +360°F (180°C) - Remote
  • Process connections : Wafer, ANSI or DIN Flanges, Insertion-Type
  • Accuracy : std - ±0.5% / opt - ±0.2%
  • Outputs : Pulse, 4-20mA, MODBUS, HART
  • Special Features : Conductivity > 5 µS/cm, velocity 0.2 - 12 m/s
  • Approvals : CE, ExdIIBT3~T6 (ATEX)
  • Display Types : Integral and Remote

Battery Powered電磁流量計 ALMAGBAT

  • Available in ¼" - 24" (3-600 mm) line sizes
  • Will measure a wide range of fluid velocities; 0-50 feet/sec (0-15 m/s)
  • GPRS, CDMA and SRD radio communications available
  • Conductivity of measured medium: ≥ 20 μs/cm
  • IP68 enclosure; suitable for underground applications
  • Available FEP liner suitable for vacuum applications
  • Excellent accuracy; ±0.5% of reading
  • Empty pipe, current excitation and remaining battery life alarms
  • NIST traceable calibration certificate

插入式電磁式流量計 ALMAGIS

  • Applicable sizes: 2"~120" (50~3000 mm)
  • Operating pressure: = 230 psig (1.6MPa) max.
  • Velocity range of 3-33 fps (1~10m/s)
  • Accuracy: ±1.5%
  • Hot-tap ball valve option allows sensor to be installed and retracted from process piping without shutting down the process
  • Conductivity of measured medium: ≥ 20 μs/cm
  • Electrode materials: 316L, Hastelloy, Ti, Ni, Tantalum
  • Max. distance between sensor and converter: 165 feet (50 m)
  • NIST traceable calibration certificate

科里奧力質量流量計 ALCM-MB

  • Suitable for aggressive & contaminated media
  • Measurement of mass flow, density, temperature & volume flow
  • High rotation frequency & well-balanced measuring tubes
  • Excellent purging & sterilization capabilities thanks to a construction that is free of dead spots
  • Operates at temps up to 575°F (300°C)
  • Individual 8-point-calibration including report
  • Optional EX protection
  • Flow Range : 3,300 ~ 2,200,000 lb/hr (1,500~1,000,000 kh/hr)
  • Size : 1/2"~8" (15~200 mm) Flanged (ANSI, DIN, Tri-Clamp®)
  • Tube geometry : U-Tube with MIcro Bend)

科里奧力質量流量計 ALCM-DT

  • Measurement of mass flow, density, temperature & volume flow
  • Suitable for aggressive & contaminated media
  • Measurement & display of percent water-cut for oil/water mixtures
  • Excellent purging & sterilization capabilities thanks to dead spot-free construction
  • High rotation frequency & well-balanced measuring tubes
  • Operates at temperatures up to 575°F (300°C)
  • Individual 8-point calibration including NIST-traceable report
  • Optional EX protection
  • Flow Range : 150 ~ 900,000 kg/hr
  • Size : 1/2" ~ 8"(15~200 mm)

科里奧力質量流量計 ALCM-UT

  • Suitable for aggressive & contaminated media
  • Measurement of mass flow, density, temperature & volume flow
  • Measurement & display of percent water-cut for oil/water mixtures
  • Excellent purging & sterilization qualities thanks to a construction that is free of dead-spots
  • High rotation frequency & well-balanced measuring tubes
  • Operating temperatures up to 575°F (300°C)
  • Individual 8-point calibration including NIST-traceable report
  • Optional EX protection
  • Flow Range : 1,500~1,000,000 kg/hr
  • Line Sizes : 1¼”~8” (40-200 mm)

夾管式超音波流量計 ALSONIC FX

  • 2 line LCD display with flowrate, totalizer & signal condition
  • Stores up 64 day/months totalizer daily value
  • Batch control function
  • Wide range of velocities, from ±0.03 to ±105 feet/sec
  • Transducers for pipe sizes ranging from ½" to 240" (13 to 6000 mm)
  • High accuracy: ± 0.5% of reading
  • Clamp on flow meter transducers feature integral magnet for installation on metal pipe without use of a mounting belt
  • Data logger function includes date, totalizer, & signal condition diagnostic
  • Fast response time: less than 1 second

熱質式質量流量計 ATMF8000 IS

  • Direct mass flow measurement of any gas with actual gas calibration
  • Opto-isolated outputs, with graphic display
  • Tracking of overall gas consumption over a turndown ratio of at least 100:1
  • Up to four independent, switchable flow curves
  • High contrast photo-emissive OLED display with rate, total, temperature and graphic display
  • User-selectable engineering units, dynamically converts the flow rate and total flow
  • Can measure higher velocity than any other thermal mass meter - up to 203 m/s
  • Display calibration milliwatt (mw) for ongoing diagnostics
  • Standard software available multi-curve fit programs
  • Low power dissipation under 2W
  • Hot-tap ball valve kit available

金屬管變面積式流量計 ALVAMT

  • Versatile design may be used for gas, steam, and liquids
  • High resolution and fast response time; - 5 to 50 msec
  • Wide temperature range from -40 up to 750 °F (-40 to 400 °C)
  • High pressure operation up to 6100 psi (420 bar)
  • Process connections including NPT threads, ANSI flanged, & Tri-Clamp available
  • Electronics either intrinsically safe EEx ia II CT5, or Ex proof EEx d II CT6
  • Wide array of materials available including Hastelloy B & C,Ti, Cu, Al, etc..
  • PTFE and other liner materials available
  • NIST-traceable calibration

Vortex渦流式流量計 ALVT系列

  • Suitable for a wide variety of applications with steam, gas, and liquid medias
  • No moving parts, high reliability and durability
  • Piezo-electric sensor isolated from the process fluid
  • Error messages displayed for or erratic flows and flows outside of calibrated ranges
  • Field calibration possible with integral or remote electronics and keypad
  • True 2-wire 4-20 mA interface
  • Wide measuring range, turn-down ratio of 10:1
  • Insertion meters can be installed vertically, horizontally or in angled pipelines
  • Available and an integrated mass flow vortex
  • ALVTIS (insertion) can be hot-tapped with ball valve and retractable assembly

  • Suitable for a wide variety of applications with steam, gas, and liquid medias
  • No moving parts and no leak paths; no o-ring or graph oil seals to wear, fail or leak
  • Two independent sensors , allowing for better signal amplification and noise reduction
  • Error messages displayed for or erratic flows and flows outside of calibrated ranges
  • Field calibration possible with integral or remote electronics and keypad
  • True 2-wire 4-20 mA interface
  • Wide measuring range, turn-down ratio of 30:1
  • Insertion meters can be installed vertically, horizontally or in angled pipelines
  • Can measure at Reynolds Numbers ranging from 10,000 to 7,000,000
  • Weather proof multi-pole connector for power, signal and serial interface
  • ALVTN (insertion) can be hot-tapped with ball valve and retractable assembly
  • ALVTN (inline) can have reduced flow body for lower flows (see drawings) than standard sizes